Tổng tiền hàng:
¥0,00() / 0 pcs
下单提醒:开票另加税点 详细咨询客服哦
![]() |
A. SCOPE
This specification applies piezo buzzer, FSR-2310A
B. SPECIFICATION
No. |
Item |
Unit |
Specification |
Condition |
1 |
Oscillation Frequency |
Hz |
4000 |
square wave |
2 |
Operating Voltage |
Vp-p |
1 ~25 |
|
3 |
Rated Voltage |
Vp-p |
5 |
|
4 |
Current Consumption |
mA |
MAX. 2 |
at Rated Voltage |
5 |
Sound Pressure Level |
dB |
MIN. 85 |
at 10cm at Rated Voltage |
6 |
Electrostatic Capacity |
pF |
15000±30% |
at 100Hz 1V |
7 |
Operating Temperature |
℃ |
-40~ +85 |
|
8 |
Storage Temperature |
℃ |
-40 ~ +90 |
|
9 |
Dimension |
mm |
Φ13.8 x H6.8 |
See appearance drawing |
10 |
Weight (MAX) |
gram |
4.7 |
|
11 |
Housing Material |
MPPO( Black ) |
||
12 |
Leading Pin |
Tin Plated Brass(Sn) |
See appearance drawing |
|
13 |
Environmental |
RoHS |
C. APPEARANCE DRAWING
Tol :±0.5 Unit:mm
D.TESTING METHOD
Standard Measurement conditions
Temperature:25±2℃ Humidity:45-65%
Acoustic Characteristics:
The oscillation frequency, current consumption and sound pressure are measured by the measuring instruments shown below
In the measuring test, buzzer is placed as follows:
E. Typical Frequency Response Curve
F RELIABILITY TEST
NO. |
ITEM |
TEST CONDITION AND REQUIREMENT |
1 |
High Temperature |
After being placed in a chamber with 90 |
2 |
Low Temperature |
After being Placed in a chamber with -40 |
3 |
Humidity Test |
After being Placed in a chamber with 90-95% R.H. at 40 |
4 |
Temperature Cycle |
The part shall be subjected to 5 cycles. One cycle shall be consist of: |
5 |
Drop Test |
Drop on a hard wood board of 4cm thick, any directions ,6 times, at the height of 75cm . |
6 |
Vibration Test |
After being applied vibration of amplitude of 1.5mm with 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours . |
7 |
Solderability |
Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of +270 |
8 |
Terminal Strength |
The force of 9.8N(1.0kg) is applied to each terminal in axial direction for 10 seconds. |
TEST CONDITION.
Standard Test Condition : a) Temperature :+5 ~ +35℃ b) Humidity :45-85% c) Pressure :860-1060mbar
Judgment Test Condition : a) Temperature :+25 ±2℃ b) Humidity :60-70% c) Pressure :860-1060mbar
G. PACKING STANDARD